Experimental study on the characteristics of heat transfer and pressure drop of steam condensation in desalination plate evaporator
Received date: 2014-06-19
Revised date: 2014-08-08
Online published: 2015-05-15
苏国萍 , 张建丽 , 周洪光 , 杜小泽 , 唐大伟 . 板式蒸发器冷凝侧传热及压降性能实验研究[J]. 中国科学院大学学报, 2015 , 32(3) : 295 -300 . DOI: 10.7523/j.issn.2095-6134.2015.03.002
The characteristics of heat transfer and pressure drop of the steam condensation in plate evaporator were analyzed based on experiment platform of the steam condensation test. The properties of heat transfer of steam condensation in herringbone plate evaporator were predicted by using the two-phase flow condensation model. A correlation of steam condensation heat transfer coefficient in herringbone plate evaporator was fitted by the multiple linear regression analysis method. Pressure drop per unit length along herringbone plate increased with the velocity of steam. Several pressure drop models of steam condensation in herringbone plate evaporator were compared. The experimental correlation between steam condensation friction factor and the equivalent Reynolds number was derived.
[1] Akili D K, Ibrahim K K, Wie J M. Advances in seawater desalination technologies [J]. Desalination, 2008, 221: 47-69.
[2] Tonner J B, Hinge S. Plate heat exchangers:the new trend in thermal desalination [J]. Desalination, 1999, 125: 243-249.
[3] Kafi F, Renaudin V. New MED plate desalination process: thermal performances [J]. Desalination, 2004, 166: 53-62.
[4] Wang L, Sunden B. Pressure drop analysis of steam condensation in a plate heat exchanger [J]. Heat Transfer Engineering, 1999, 20(1): 71-77.
[5] 王列科,杨强生. 板式换热器中蒸汽凝结换热特性[J]. 上海交通大学学报,1998, 32(4): 18-22.
[6] Kuo W S, Lie Y M,Hsieh Y Y, et al. Condensation heat transfer and pressure drop of refrigerant R-410A flow in a vertical plate heat exchanger [J]. International Journal of Heat and Mass Transfer, 2005, 48 (25/26): 5 205-5 220.
[7] Longo G A. Refrigerant R134a condensation heat transfer and pressure drop inside a small brazed plate heat exchanger[J]. International Journal of Refrigeration, 2008, 31(5): 780-789.
[8] Longo G A. R410A condensation inside a commercial brazed plate heat exchanger[J]. Experimental Thermal and Fluid Science, 2009, 33(2): 284-291.
[9] Longo G A. Heat transfer and pressure drop during HFC refrigerant saturated vapour condensation inside a brazed plate heat exchanger[J]. International Journal of Heat and Mass Transfer, 2010, 53(5/6):1 079-1 087.
[10] Mancin S, Del C D,Rossetto L. Partial condensation of R407C and R410A refrigerants inside a plate heat exchanger[J]. Experimental Thermal and Fluid Science, 2012, 36:149-157.
[11] Wang Z, Zhao Z. Analysis of performance of steam condensation heat transfer and pressure drop in plate condensers[J]. Heat Transfer Engrg, 1993, 14 (4): 32-41.
[12] Jokar A, Hosnil M H. Dimensional analysis on the evaporation and condensation of refrigerant R-134a in minichannel plate heat exchangers[J]. Applied Thermal Engineering, 2006, 26(17/18):2 287-2 300.
[13] Mancin S, Del C D. Condensation of superheated vapor of R410A and R407C inside plate heat exchangers: experimental results and simulation procedure [J].International Journal of Refrigeration, 2012, 35(7):2 003-2 013.
[14] Hsieh Y Y, Lin T F. Evaporation heat transfer and pressure drop of refrigerant R-410a flow in a vertical plate heat exchanger[J]. Journal of Heat Transfer (Transactions of the ASME), 2003, 125 (5): 852-857.
[15] Yan Y Y, Lin T F. Evaporation heat transfer and pressure drop of refrigerant R-134a in a plate heat exchanger[J]. Journal of Heat Transfer (Transaction of the ASME), 1999, 121 (1): 118-127.
/
| 〈 |
|
〉 |