欢迎访问中国科学院大学学报,今天是
研究论文

电容电导传感器油水两相流含率测量

  • 吴昊 ,
  • 谭超 ,
  • 董峰
展开
  • 天津大学电气与自动化工程学院天津市过程检测与控制重点实验室, 天津 300072

收稿日期: 2016-04-21

  修回日期: 2016-07-06

  网络出版日期: 2017-03-15

基金资助

国家自然科学基金(61227006,61473206)资助

Capacitance-conductance sensor for water holdup measurement in oil-water two-phase flow

  • WU Hao ,
  • TAN Chao ,
  • DONG Feng
Expand
  • Tianjin Key Laboratory of Process Measurement and Control, School of Electrical Engineering and Automation, Tianjin University, Tianjin 300072, China

Received date: 2016-04-21

  Revised date: 2016-07-06

  Online published: 2017-03-15

摘要

在油水两相流测量中,利用电容传感器和电导传感器在含率测量上有不同的敏感范围,设计一种电容电导传感器,使用电子开关实现两种测量方法的快速切换,使其在相同敏感场内测量。新型电容电导传感器实现了对水平管道内低电导率水(自来水)组成的油水两相流的全含率范围的测量,利用快关阀进行标定,其含率测量误差小于±5% 。

本文引用格式

吴昊 , 谭超 , 董峰 . 电容电导传感器油水两相流含率测量[J]. 中国科学院大学学报, 2017 , 34(2) : 237 -243 . DOI: 10.7523/j.issn.2095-6134.2017.02.018

Abstract

In oil-water two-phase flow measurement, a capacitance-conductance sensor has been designed based on the fact that the capacitance sensor and conductance sensor realize the water holdup measurement in different situations with different sensitive ranges. Electrical switches are used to switch the two measurement methods at high speed in order to make them have the same sensitive fields. The disigned sensor realizes the whole fraction measurement in oil-water two-phase flow with low conductivity water (tap water) and the water holdup measurement error is less than 5[WTB4]%[WTBZ].

参考文献

[1] Xie C G, Reinecke N, Beck M S, et al. Electrical tomography techniques for process engineering applications[J]. The Chemical Engineering Journal and the Biochemical Engineering Journal, 1995, 56(3):127-133.
[2] Zhao X, Lucas G P. Use of a novel dual-sensor probe array and electrical resistance tomography for characterization of the mean and time-dependent properties of inclined, bubbly oil-in-water pipe flows[J]. Measurement Science and Technology, 2011, 22(10):104012.
[3] Ismail I, Gamio J C, Bukhari S F, et al. Tomography for multi-phase flow measurement in the oil industry[J]. Flow Measurement and Instrumentation, 2005, 16(2):145-155.
[4] Dong F, Liu X P, Deng X, et al. Identification of two-phase flow regimes in horizontal, inclined and vertical pipes[J]. Measurement Science and Technology, 2001, 12(8):1069-1075.
[5] Fossa M. Design and performance of a conductance probe for measuring the liquid fraction in two-phase gas-liquid flows[J]. Flow Measurement and Instrumentation, 1998, 9(2):103-109.
[6] Devia F, Fossa M. Design and optimisation of impedance probes for void fraction measurements[J]. Flow Measurement and Instrumentation, 2003, 14(4):139-149.
[7] Dang R R, Zhao D S, Li L P, et al. The flow measurement of multiphase flow based on the conductance sensor[J]. Modern Instrumentation, 2012, 1(4):35-40.
[8] Abouelwafa M S A, Kendall E J M. The use of capacitance sensors for phase percentage determination in multiphase pipelines[J]. IEEE Transactions on Instrumentation and Measurement, 1980, 29(1):24-27.
[9] Jaworek A, Krupa A. Gas/liquid ratio measurements by RF resonance capacitance sensor[J]. Sensors and Actuators A:Physical, 2004, 113(2):133-139.
[10] Reis E D, Cunha D S. Experimental study on different configurations of capacitive sensors for measuring the volumetric concentration in two-phase flows[J]. Flow Measurement and Instrumentation, 2014, 37:127-134.
[11] Wu H, Tan C, Dong X, et al. Design of a conductance and capacitance combination sensor for water holdup measurement in oil-water two-phase flow[J]. Flow Measurement and Instrumentation, 2015, 46(B):218-229.
[12] 施艳艳,董峰,谭超.两相流测量中环形电导传感器特性研究[J].中国电机工程学报,2010,30(17):62-66.
[13] 董虓霄,谭超,董峰.油水两相流含水率测量组合传感器[J].工程热物理学报,2015,36(7):1487-1491.
[14] Yang W Q. Hardware design of electrical capacitance tomography systems[J]. Measurement Science and Technology, 1996, 7(3):225-232.
[15] Trallero J L, Sarica C, Brill J P. A study of oil/water flow patterns in horizontal pipes[J]. SPE Production & Facilities, 1997, 12(3):165-172.
文章导航

/