Journal of University of Chinese Academy of Sciences >
Hygroscopic properties of the ambient aerosols observed in winter in Beijing
Received date: 2013-07-15
Revised date: 2013-09-23
Online published: 2014-05-15
By using HTDMA (hygroscopic tandem differential mobility analyzer) system, hygroscopicity of ambient aerosols was observed during 8-20 December 2009 in Beijing. It was found that the aerosol hygroscopic growth factor value varied between 1.01 and 1.40 in winter, showing weak hygroscopicity and nearly hydrophobicity. Daily variation of aerosol growth factor showed a bimodal mode (two peaks at midnight and noon and two valleys in the morning and evening rush hour) or a single-peak mode (a peak at midnight and a valley at noon). One of the major factors influencing aerosol hygroscopicity was the content of weak hygroscopic and nearly hydrophobic components in the ambient aerosol.
Key words: field observation; aerosols; hygroscopic properties; Beijing
WANG Xuan , CHEN Jianhua , GENG Chunmei , REN Lihong , CHEN Jianmin , YE Xingnan , YANG Wen . Hygroscopic properties of the ambient aerosols observed in winter in Beijing[J]. Journal of University of Chinese Academy of Sciences, 2014 , 31(3) : 322 -328 . DOI: 10.7523/j.issn.2095-6134.2014.03.005
[1] Gasparini R, Li R J, Collins Don R. Integration of size distributions and size-resolved hygroscopicity measured during the Houston Supersite for compositional categorization of the aerosol[J]. Atmospheric Environment, 2004,38: 3285-3303.
[2] Dentener J F, Crutzen J P. Reaction of N2O5 on tropospheric aerosols impact on the global distributions of NOx, O3, and OH[J]. Journal of Geophysical Research, 1993, 98:7149-7163.
[3] Malm C W, Day E D. Estimates of aerosol species scattering characteristics as a function of relative humidity[J]. Atmospheric Environment, 2001, 35:2845-2860.
[4] Brechtel J F, Kreidenweis M S. Predicting particle critical supersaturation from hygroscopic growth measurements in the humidified TDMA. Part I: theory and sensitivity studies[J]. Journal of the Atmospheric Sciences, 2000,57: 1854-1871.
[5] Broday M D, Georgopoulos G P. Growth and deposition of hygroscopic particulate matter in the human lungs[J]. Aerosol Science and Technology, 2001,34:144-159.
[6] Londahl J, Massling A, Pagels J, et al. Size-resolved respiratory-tract deposition of fine and ultrafine hydrophobic and hygroscopic aerosol particles during rest and exercise[J]. Inhal Toxicol.2007,19(2):109-116.
[7] Wang X, Chen J H, Wang W. Review of study in hygroscopic properties of aerosol particles[J]. China Powder Science and Technology, 2010, 16(1):101-107 (in Chinese). 王轩,陈建华,王玮.气溶胶吸湿特性研究现状[J].中国粉体技术,2010, 16(1):101-107.
[8] Rader D J, McMurry P H. Application of the tandem differential mobility analyzer to studies of droplet growth or evaporation[J]. Journal of Aerosol Science, 1986,17(5): 771-787.
[9] McMurry H P, Stolzenburg R M. On the sensitivity of particle size to relative humidity for Los Angeles aerosols[J]. Atmospheric Environment, 1989, 23: 497-507.
[10] Liu B Y H, Pui D Y H, Whitby K T, et al. The aerosol mobility chromatograph: a new detector for sulfuric acid aerosols[J]. Atmospheric Environment, 1978, 12: 99-104.
[11] Pitchford M L, McMurry P H. Relationship between measured water vapor growth and chemistry of atmospheric aerosol for Grand Canyon, Arizona, in winter 1990[J]. Atmospheric Environment,1994, 28: 827-839.
[12] McMurry P H, Litchy M, Po-Fu H, et al. Elemental composition and morphology of individual particles separated by size and hygroscopisity with the TDMA[J]. Atmospheric Environment, 1996, 30: 101-108.
[13] Buzorius G, Zelenyuk A, Brechtel F, et al. Simultaneous determination of individual ambient particle size, hygroscopicity and composition[J]. Geophysical Research Letters, 2002, 29(20):1029-1039.
[14] Weingartner E, Gysel M, Baltensperger U. Hygroscopicity of aerosol particles at low temperatures. 1. new low-temperature H-TDMA instrument: setup and first applications[J]. Environmental Science & Technology, 2002, 36, 55-62.
[15] YE X N, CHEN T Y, Hu D W, et al. A multifunctional HTDMA system with a robust temperature control[J]. Advances in Atmospheric Sciences, 2009, 26(6): 1235-1240.
[16] Swietlicki E, Hansson H C, Hmeri K, et al. Hygroscopic properties of submicrometer atmospheric aerosol particles measured with H-TDMA instruments in various environments:a review[J]. Tellus, Series B, Chemical and Physical Meteorology, 2008,60(B): 432-469.
[17] Gysel M, McFiggans G B, Coe H. Inversion of tandem differential mobility analyser(TDMA) measurements[J]. Aerosol Science, 2009, 40:134-151.
[18] Massling A, Stock M, Wiedensohler A. Diurnal, weekly, andseasonal variation of hygroscopic properties of submicrometer urban aerosol particles[J]. Atmospheric Environment, 2005,39:3911-3922.
[19] Yan P, Pan X L, Tang J, et al. An experimental study on the influence of relative humidity on the atmospheric aerosol scattering coefficient at an urban site in Beijing[J]. Acta Meteorologica Sinica, 2008, 66 (1):111-119 (in Chinese). 颜鹏,潘晓乐,汤洁,等. 北京市区大气气溶胶散射系数亲水增长的观测研究[J].气象学报,2008, 66 (1):111-119.
[20] Cocker III R D, Whitlock E N, Flagan C R, et al. Hygroscopic properties of pasadena, California aerosol[J]. Aerosol Science and Technology, 2001, 35: 637-647.
[21] Dua S K, Hopke P K, Raunemaa T. Hygroscopicity of diesel aerosols[J]. Water, Air, and Soil Pollution, 1999,112: 247-257.
[22] Weingartner E, Baltensperger U, Burtscher H. Hygroscopic properties of carbon and diesel soot particles[J]. Atmospheric Environment, 1997.31: 2311-2327.
[23] Wang X, Chen J H, Chen J M, et al. Characterization of hygroscopic properties of laboratory-generated nanometer aerosols[J].Research of Environmental Sciences, 2011,24(6):30-40 (in Chinese). 王轩,陈建华,陈建民,等.实验室发生气溶胶吸湿特性研究[J].环境科学研究,2011,24(6):30-40.
/
| 〈 |
|
〉 |