Based on the double boundary layer model, this work established a laminar condensation heat transfer model of steam with CO2 on a vertical plate. The condensation heat transfer performance is deteriorated greatly due to the presence of CO2. At a certain concentration of CO2, with the increase of surface sub-cooling, the heat flux increases, the heat transfer coefficient decreases, and the interface temperature decreases almost linearly. With the increase of CO2 concentration, the heat transfer coefficient decreases rapidly while the interface temperature increases gradually. In addition, the presence of CO2 results in the formation of a layer of gas film outside the liquid film. With the increase of surface sub-cooling, the thickness of liquid film increases and the thickness of gas film decreases. Hoowever the thickness of the gas film is one order of magnitude larger than that of the liquid film. With the increase of CO2 concentration, the thicknesses of liquid film and gas film both increase. However, the thermal resistance ratio of gas film to liquid film increases gradually, and the gas thermal resistance becomes dominant at high concentrations of CO2.
GE Minghui
,
YU Ranran
,
ZHAO Jun
,
LIU Liansheng
. Condensation heat transfer characteristics of steam with CO2[J]. Journal of University of Chinese Academy of Sciences, 2018
, 35(2)
: 275
-279
.
DOI: 10.7523/j.issn.2095-6134.2018.02.019
[1] Gouedard C, Picq D, Launay F, et al. Amine degradation in CO2 capture. I. A review[J]. International Journal of Greenhouse Gas Control, 2012, 10:244-270.
[2] Yin J Y, Qin C L, An H, et al. High-temperature pressure swing adsorption process for CO2 separation[J]. Energy & Fuels 2012, 26:169-175.
[3] Ambrosini W, Forgione N, Manfredini A, et al. On various forms of the heat and mass transfer analogy:discussion and application to condensation experiments[J]. Nuclear Engineering and Design, 2006,236:1013-1027.
[4] Dehbi A, Janasz F, Bell B. Prediction of steam condensation in the presence of noncondensable gases using a CFD-based approach[J]. Nuclear Engineering and Design, 2013,258:199-210.
[5] Maria P. Condensation of water vapor and acid mixtures from exhaust gases[D]. Germany:Technische Universität, 2004.
[6] Maheshwari N, Saha D, Sinha R, et al. Investigation on condensation in presence of a noncondensable gas for a wide range of Reynolds number[J]. Nuclear Engineering and Design, 2004,227:219-238.
[7] Chantana C, Kumar S. Experimental and theoretical investigation of air-steam condensation in a vertical tube at low inlet steam fractions[J]. Applied Thermal Engineering, 2013,54:399-412.
[8] Hogan K, Liao Y, Beeny B, et al. Implementation of a generalized diffusion layer model for condensation into MELCOR[J]. Nuclear Engineering and Design, 2010,240:3202-3208.
[9] 彭文平. 汽-气凝结气、液膜厚度及换热特性的研究[D]. 北京:华北电力大学, 2013.